Light-Protected Soft-Shell Infusion Pump

An elastomeric reservoir inside a light-protected soft body, with the line and the accessories protected from light as well.

Manufacturer: Tuoren MedicalClass IIa3 SUT codes9 models

This page is intended for healthcare professionals.

Light-Protected Soft-Shell Infusion Pump

Measurements at a glance

Fill volume
100/275 ml
by model
Flow rate
1.5/2/4/5 ml/h
by model
Filter
1.2/5.0 µm
by model

Models

Fill volume (ml)Flow rate (ml/h)Filter (µm)SUT codeModel
100 ml bottle
10025.0OR1810SUCBI10020L50
10041.2OR1810SUCBI10040L12
10045.0No codeSUCBI10040L50
275 ml bottle
2751.51.2OR1830SUCBI27515L12
2751.55.0No codeSUCBI27515L50
27521.2OR1820SUCBI27520L12
27525.0No codeSUCBI27520L50
27551.2OR1810SUCBI27550L12
27555.0No codeSUCBI27550L50
Fill volumes
100 and 275 ml
Flow rates
One fixed rate per item: 1.5, 2, 4 and 5 ml/h
Flow accuracy
Within plus minus 10 per cent of the nominal rate
Medicine filter
A 1.2 or 5.0 micrometre filter at the line outlet; the L12 and L50 suffix of the catalogue number says which
On the line
Total length at least 110 cm, with a check-valve filling port, a clamp and a patient-end cap; Luer and NRFit connections are listed for the soft family
Filling and priming
Filled with 10 ml of diluent first and primed; priming takes about half a minute and stays within three minutes. Infusion is started 0 to 8 hours after filling
Delivered and residual volume
At least 90 per cent of the nominal volume is delivered; at most 3 ml stays behind, tubing included
Diluent
The nominal rate holds with 5 per cent dextrose or 0.9 per cent sodium chloride

A catalogue number writes the type, the volume, the flow rate and the filter pore together: SUCBI10040L12 is the light-protected soft body at 100 ml, 4 ml/h and a 1.2 micrometre filter.

A single-use elastomeric infusion pump with a soft outer body, whose reservoir, line and accessories are protected from light.

In which cases?

  • An infusion that continues at home with a light-sensitive drug, the pump carried under clothing.
  • Ambulatory infusion where the volume left is followed on the body of the pump.
  • Patients moving between the hospital and home care.
  • Regimens whose duration is set by the bottle volume and the flow rate: about twenty five hours at 100 ml and 4 ml/h, about seven and a half days at 275 ml and 1.5 ml/h.

What makes it different?

  • The soft outer body takes less room in storage and in transport.
  • The infused volume is followed visually on the body of the pump.
  • Luer and NRFit connections are listed for the soft family.

Frequently asked questions

What does the soft body change?

The soft outer body takes less room in storage and in transport, and the infused volume is followed on the body of the pump. The light protection covers the reservoir, the line and the accessories together, as it does on the rigid type.

Which volumes and rates are supplied?

Bottles of 100 ml and 275 ml, at 1.5, 2, 4 and 5 ml/h, one fixed rate per item. The models table gives the volume, the rate and the filter pore of every catalogue number.

Technical data

Manufacturer
Tuoren Medical
Class
IIa
SUT codes
OR1810OR1830OR1820
Sterility and shelf life
Sterilised with ethylene oxide, single use, shelf life 60 months
Body
A light-protected soft body holding the elastomeric reservoir, with a protective cap
Light protection
The reservoir, the tubing and the accessories are protected together
Flow control
A micro flow restrictor tube; no rate dial and no bolus button
Material
Silicone, medical PVC and ABS; latex free and DEHP free

Distributing Light-Protected Soft-Shell Infusion Pump in Türkiye

Registration, the first cases and nationwide supply are handled by one team.