A laparoscopic ultrasonic shear on the AH-600 system that seals and divides vessels up to 3 mm in diameter.

Manufacturer: AffacareClass IIb2 SUT codes7 models

This page is intended for healthcare professionals.

Ultrasonic Laparoscopic Shears

Measurements at a glance

Working length
14/23/36/45 cm
by model
Ultrasonic shears / Ultrasonik makas A
A
Working length 14 / 23 / 36 / 45 cm

Schematic, not to scale

Models

Working length (cm)Vessel (mm)HandleSUT codeModel
AH-638-B, integrated handle
14Up to 3Integrated, single useOR3280AH-638-B-T
23Up to 3Integrated, single useOR3290AH-638-B-S
36Up to 3Integrated, single useOR3290AH-638-B-L
AH-631, for handpiece AH-636-B
14Up to 3Seated in handpiece AH-636-BNo codeAH-631-T
23Up to 3Seated in handpiece AH-636-BNo codeAH-631-S
36Up to 3Seated in handpiece AH-636-BNo codeAH-631-L
45Up to 3Seated in handpiece AH-636-BNo codeAH-631-O
Trocar requirement
Inner diameter over 5.5 mm, CE marked
Handle
AH-638-B integrated; the AH-631 shaft seats in handpiece AH-636-B
Drive frequency
55 kHz ± 1 kHz at all five power levels

A family of single-use ultrasonic shears for laparoscopic procedures at working lengths of 14, 23, 36 and 45 cm, which cut soft tissue and coagulate it in the same closure: AH-638-B and AH-631.

In which cases?

  • Sealing and dividing vessels up to 3 mm in diameter during dissection.
  • Open or laparoscopic general, gynecologic, urologic and thoracic procedures.

What makes it different?

  • One movement, two jobs the jaw heats the tissue it holds and divides it in the same closure.
  • Two builds of the same jaw an integrated single-use handle on the AH-638-B and a shaft that seats in the reusable AH-636-B handpiece on the AH-631.
  • MAX and MIN on the handle the power level shown on the generator screen is changed from the hand that holds the instrument.

Frequently asked questions

What is the difference between the AH-638-B and the AH-631?

The jaw and the indication are the same and the build differs. The AH-638-B carries its own housing and trigger handle and is discarded whole after the case. The AH-631 is the shaft alone and is seated in the reusable handpiece AH-636-B, so a theatre that keeps the handpiece reorders shafts. Both families are rated for vessels up to and including 3 mm in diameter.

Which trocar is it used with?

CE-marked trocars and endoscopes are required, and the trocar inner diameter has to be greater than 5.5 mm. Choosing a trocar and an endoscope that meet the requirement is left to the user.

Technical data

Manufacturer
Affacare
Class
IIb
SUT codes
OR3280OR3290
Sterilization
Ethylene oxide, sterile from the factory, single use