A visual laryngeal mask airway (visual LMA) is a supraglottic airway device with a viewing channel on the left side of the ventilation channel, showing the whole glottis. A sealed cap keeps the camera off the mucosa. Double drainage serves the larynx and the stomach. The video laryngeal mask is a separate product. Sizes: 3.0, 4.0, 5.0.
This page is intended for healthcare professionals.
| Size | Model |
|---|---|
| 3.0 | LMAV430 |
| 4.0 | LMAV440 |
| 5.0 | LMAV450 |
Visual laryngeal mask airway that shows the whole glottis from the side of the ventilation channel, with a covered viewing channel, double drainage and sizes 3.0 to 5.0.
| Feature | Video Laryngeal Mask Airway Coming Soon | Visual Laryngeal Mask Airway Coming Soon | Blockbuster Intubating Laryngeal Mask Airway Coming Soon |
|---|---|---|---|
| View | Video LMACamera in the lumen, image on the TR-V-01 monitor, alarm on displacement | Visual LMAWhole glottis, through the covered viewing channel beside the ventilation channel | BlockbusterNo camera: the tube is passed blind or with a fiberscope |
| Gastric tube and drainage | Video LMAA gastric tube can be inserted | Visual LMADouble drainage for the larynx and the stomach | BlockbusterGastric access channel |
| Intubation through the mask | Video LMAEndotracheal tube exchange through the mask | Visual LMATracheal intubation through the mask (manufacturer's statement) | BlockbusterA guidance device directs the endotracheal tube to the glottis |
| Sizes | Video LMA1.01.52.02.53.04.05.0 | Visual LMA3.04.05.0 | Blockbuster1.01.52.02.53.04.05.0 |
A visual laryngeal mask airway is a laryngeal mask with a viewing channel on the left side of the ventilation channel. Through this channel the whole glottis is seen while the mask ventilates the patient. A sealed cap keeps the camera from touching the airway mucosa directly. The mask also has double drainage for the larynx and the stomach. Sizes are 3.0, 4.0 and 5.0.
In the visual laryngeal mask the camera sits in a covered viewing channel beside the ventilation channel, and the mask has double drainage; sizes are 3.0, 4.0 and 5.0. In the video laryngeal mask the camera sits inside the lumen, the cuff is not inflated and an automatic alarm is given if it moves; sizes 1.0 to 5.0. The Blockbuster is a laryngeal mask for intubation, with no camera.
This page lists sizes 3.0, 4.0 and 5.0 and no child size. A laryngeal mask size is usually chosen by the patient's weight. On this site the video laryngeal mask and the Blockbuster are listed in sizes from 1.0 to 5.0. The final choice belongs to the physician.
This page does not name the camera and monitor model; the catalogue does not give this. The viewing channel has a sealed cap, so the camera does not touch the airway mucosa directly. The manufacturer states that the camera is not single use. Write to us with your camera and monitor question.
The manufacturer states that the sealed cap keeps the camera off the airway mucosa and that the camera is not single use. The cleaning and disinfection method for the camera, and how many times the mask can be used, are not on this page; the catalogue does not give this.
The mask has double drainage for the larynx and the stomach, with its own drainage cavity. This page does not say whether a gastric tube passes through the drainage channel, or which size; the catalogue does not give this. The airway choice in a patient at risk of aspiration is the physician's decision.
The manufacturer states that the design angle follows the airway and is meant to guide tracheal intubation to the glottis. The endotracheal tube diameter that passes each size is not listed on this page. The method is the physician's choice. The laryngeal mask built for intubation on this site is the Blockbuster.
We can share the product documents and the catalogue sizes, 3.0, 4.0 and 5.0. Not yet: the visual laryngeal mask airway is not available for order in Türkiye, so this page carries no list price. Write to us with the button on this page for information, including camera and monitor questions.
Updated: 10.11.2026