Polypectomy Snare

A wire loop on a sheath, closed around a polyp and cut cold or with current; single-use and reusable families.

Manufacturer: Medi-Globe / Endo-FlexClass IIb2 SUT codes20 models

This page is intended for healthcare professionals.

Polypectomy Snare

Models

LoopSUT codeModel
OvalGS1160NOE341816-C
OvalGS1160NOE342212M-G
OvalGS1160NOE342213-G
OvalGS1160NOE342213M-G
OvalGS1160NOE342214-C
OvalGS1160NOE342214-G
OvalNo codeNOE342214-M
OvalGS1160NOE342214M-G
OvalGS1160NOE342216-C
OvalGS1160NOE342216-G
OvalNo codeNOE342216M-G
OvalNo codeNOE342217-C
OvalGS1160NOE342217-G
OvalNo codeNOE342217M-C
OvalNo codeNOE342217M-G
HexagonalGS1170NOE372214-G
HexagonalGS1170NOE372216-G
HexagonalGS1170NOE372217-G
AsymmetricNo codeNOE3222-G
AsymmetricNo codeNOE3322-G

The table lists the single-use family; the fifteen models of the reusable family are not in it.

A wire loop snare used to resect pedunculated and sessile polyps during colonoscopy and gastroscopy.

In which cases?

  • Cold snare polypectomy of a small polyp during screening colonoscopy.
  • A pedunculated polyp taken hot, with the stalk transected in one pass.
  • A large sessile lesion removed piecemeal across several passes.
  • A mucosectomy where the lesion is lifted first and then taken with the loop.

What makes it different?

  • Oval, hexagonal and asymmetric loops, matched to the lesion.
  • Monofilament or braided wire, so the cut is set for a thin or a thick stalk.
  • Rotates through 360 degrees, so the loop is turned onto a polyp sitting behind a fold.
  • Insulated tip versions, so the sheath tip is not a current path against the wall.
  • Single-use and reusable families, so the unit chooses between a sterile pack and a reprocessed loop.

Frequently asked questions

What is the difference between the single-use and the reusable snare?

Reprocessing and what it costs. The single-use snare comes sterile with a 36 month shelf life. The reusable snare is supplied non-sterile, is steam sterilized before every use and is allowed no more than 30 cycles; eleven of its models also carry an MR unsafe statement on the label, which is the line to check before a patient goes into the scanner.

Which loop shapes are supplied?

Three shapes in the single-use family: an oval loop on fifteen models, a hexagonal loop on three and an asymmetric loop on two. The models table gives the loop shape of every order number.

Technical data

Manufacturer
Medi-Globe / Endo-Flex
Class
IIb
SUT codes
GS1160GS1170
Sterilization
The single-use family is sterile from the factory with a 36 month shelf life; the reusable family is supplied non-sterile and is sterilized before every use
Latex
Does not contain latex
MRI
Eleven of the reusable models carry an MR unsafe statement on the label; the others carry no MR statement
Continuous use
Designed for continuous use of less than 60 minutes
Reprocessing limit
The reusable family is allowed no more than 30 cycles
Contraindications
Application to the central cardiovascular system, coagulopathy and haemorrhagic diathesis, and use in a patient with Creutzfeldt Jakob disease
Use
Two families: single-use and reusable