claire® neo Safety Cabinet
A cytotoxic safety cabinet protects the person compounding, the drug and the room while chemotherapy drugs are prepared. Berner claire neo is offered as a cytostatic safety cabinet to DIN 12980:2017-05, and the same model is ordered as a biological safety cabinet (biosafety cabinet) to DIN EN 12469:2026. The width is chosen in 30 cm steps, and the third HEPA filter stage can be added later on site.
Six details
- 1
Shield design
The Shield Design brings form and function together. The manufacturer states that claire neo received the Red Dot Design Award 2024 and two iF Design Awards 2025, for product design and user interface.
- 2
LED status light
Besides the LED light of the workspace, light bands at the sides and the illuminated window edge in the user's view show the operating state and alarms.
- 3
Touch control
Swipe gestures work with gloves; 15 function keys are assigned by drag and drop; users log in with a code or an RFID chip.
- 4
Movement-Measurement-System
It detects people moving near the work opening and the air disturbance they cause, and gives a clear warning.
- 5
Monitor in the back wall
A 22-inch monitor can be fitted into the back wall on site, later as well.
- 6
Height and legroom
The first main filter stage is compact, so there is room for the legs even with 3 filters. The electric base frame moves the worktop between 725 and 1125 mm.
From 2 filters to 3, on site
The airflow of claire neo leaves room for a third HEPA filter stage under the worktop. It can be ordered with the cabinet or fitted later.
- 3Exhaust filteron top, filters the air leaving the cabinet
- 2Recirculation filterabove the workspace, gives the clean downflow
- 1Main filterunder the worktop, only in the 3-filter system
- All filters at least H14 to DIN EN 1822-1.
- The third stage can be fitted on site later; almost all parts of the 2-filter cabinet stay in use.
- The manufacturer calls the third stage useful or even necessary for cytostatics and hazardous biomaterials.
Four widths, one 30 cm grid
Most safety cabinets follow HEPA filter sizes in feet, so their outer dimensions are fractional. claire neo is built in 30 cm steps at a standard depth of 800 mm: it lines up with laboratory furniture and digital room planning.
Operated by touch, linked by OPC UA
On the display
- Energy-saving dark mode
- Swipe gestures, also with gloves
- 15 function keys, assigned by drag and drop
- Login by code or RFID chip, user profiles
- Interactive error messages
- Touch-free start with the foot sensor
- Cleaning monitoring you can set up yourself
Digital link
- Optional OPC UA interface
- Link to laboratory monitoring and cleanroom control systems
- Record of all logins, alarms and errors
- Prepared for remote diagnosis and maintenance
Auto on/off
With the optional auto on/off function the cabinet notices that the user has left and shuts down in a controlled way. When the user comes back, ventilation and light switch on and the front window opens by itself.
Worktops that change with the work
- New worktop without ventilation slots: easier to clean, 12% more work surface
- Segment sets 244 mm and 300 mm wide; also 600, 900 mm and other sizes
- Reinforced worktops for weighing
- White safety glass worktops for a brighter workspace
- All worktops fit every claire neo model and can be combined
Worktops with a function
- Magnetic stirrer
- Temperature control
- LED backlight
- Keyboard
Built in flush and liquid-tight, usable as a normal surface when off, powered from below by plug and play, switched on from the touch display; the user fits and removes them.
Long life and conversion
The manufacturer's figures. Moving from 2 to 3 filters needs no new cabinet, and the metric grid makes rearranging the room easier.
claire neo XL: twice the depth
The large model of the same family, for laboratory robots, liquid handling systems, bioreactors and other bulky equipment. Several units join side by side into a containment line of several metres.
| claire neo | claire neo XL | |
|---|---|---|
| Outer width | 1200 / 1500 / 1800 / 2100 mm | 1500 / 1800 mm |
| Depth | 800 mm | 1300 mm |
| Height, standard base frame | 1967-2317 mm | 2630-3080 mm |
| Workspace width | 1100 / 1400 / 1700 / 2000 mm | 1400 / 1700 mm |
| Workspace depth | 475 mm | 950 mm |
| Workspace height | 634 mm | 990-1100 mm |
| Worktop height, electric base frame | 725-1125 mm | 760-1160 mm |
| Filters | 2 or 3, at least H14 | 2 or 3, at least H14 |
| Type | Biological or cytostatic safety cabinet | Class II biological or cytostatic safety cabinet |
Technical data
- Type of device
- Biological safety cabinet or cytostatic safety cabinet
- Type of construction
- DIN EN 12469:2026 or DIN 12980:2017-05
- Marking and certificate
- CE; TÜV GS; quality management to DIN EN ISO 9001
- Outer width
- 1200, 1500, 1800 and 2100 mm
- Depth
- 800 mm
- Height
- Standard base frame 1967 to 2317 mm; electric base frame 2042 to 2442 mm
- Clearance (H x D)
- Standard base frame 1947 x 800 mm; electric base frame 2022 x 800 mm
- Worktop height
- Standard base frame 650 to 1000 mm in 8 steps; electric base frame 725 to 1125 mm, infinitely variable
- Filters
- Main, recirculation and exhaust filter at least H14 (E ≥ 99.995%) to DIN EN 1822-1, at the most penetrating particle size
- Cleanroom class in the workspace
- EC GMP guidelines: A; DIN EN ISO 14644-1: ISO class 5
- Nominal illuminance
- min. 1 to 1200 lx
- Vibration on the worktop (RMS)
- ≤ 5 µm
- Sound pressure level (ISO 11201)
- < 65 dB(A)
- Workspace
- 1.5 mm stainless steel 1.4301 (V2A), 400 grit fine finish, Ra < 0.8 µm
- Casing
- Powder-coated 1.5 mm zinc-coated steel sheet 1.0330; white RAL 9003 matt as standard, black RAL 9005 matt as an option
- Front and side panels
- Laminated safety glass with a UV-absorbing interlayer
- Mains
- 230 V AC, 50/60 Hz
- Power consumption ECO / GMP
- 165 / 236 W (B-3-150, without extra consumers)
Frequently asked questions
What does the price of the claire neo safety cabinet depend on?
The price depends on the width, the 2 or 3 filter system, base frame, worktops and options. Write to us for a fast quote, using the contact details at the foot of this page.
What is the difference between a cytotoxic safety cabinet and a class II biosafety cabinet?
A cytotoxic (cytostatic) safety cabinet is built to DIN 12980 for the preparation of hazardous drugs. A biological safety cabinet is built to DIN EN 12469, the European standard for microbiological safety cabinets. The catalogue lists claire neo as either type; for work with cytostatics the manufacturer calls the third HEPA filter stage useful or even necessary.
What is the difference between a laminar flow cabinet and a safety cabinet?
A laminar flow cabinet blows clean air over the work and protects the product only. A safety cabinet also protects the person at the cabinet and the room. Because the person preparing hazardous drugs has to be protected too, a safety cabinet is used for them.
What is a cytotoxic safety cabinet, and is claire neo one?
A cytotoxic (cytostatic) safety cabinet protects the person compounding, the drug and the room while hazardous drugs are prepared. In Germany its type is set by DIN 12980. The catalogue lists claire neo either as a biological safety cabinet to DIN EN 12469:2026 or as a cytostatic safety cabinet to DIN 12980:2017-05. For work with cytostatics the manufacturer calls the third HEPA filter stage useful or even necessary.
What is DIN 12980?
DIN 12980 is the German standard that sets the type of a cytostatic safety cabinet, the cabinet used to prepare hazardous drugs such as cytostatics. The catalogue lists claire neo as a cytostatic safety cabinet to DIN 12980:2017-05 or as a biological safety cabinet to DIN EN 12469:2026. For work with cytostatics the manufacturer calls the third HEPA filter stage useful or even necessary.
Is claire neo a class II biological safety cabinet?
For claire neo the catalogue names the type of construction: DIN EN 12469:2026, the European standard for microbiological safety cabinets, or DIN 12980:2017-05. The larger claire neo XL of the same family is described there as a class II biological safety cabinet. The manufacturer states that both cabinets are already tested to the new DIN EN 12469:2026 and its stricter personnel, product and cross-contamination protection.
Which version suits a chemotherapy compounding unit?
For compounding cytostatics the cabinet is ordered as a cytostatic safety cabinet with the 3-filter system. The width follows the room and the number of people working: 1200, 1500, 1800 or 2100 mm. A unit that starts with a 2-filter cabinet can have the third filter stage fitted on site later. SealSafe® Pro can stand next to the cabinet and seal the waste.
What is the difference between the 2-filter and the 3-filter system?
Both have a recirculation filter above the workspace and an exhaust filter on top. The 3-filter system adds a main filter stage under the worktop: the air drawn out of the workspace passes this filter first. All three are at least H14. On claire neo this stage is compact enough to keep the legroom and can be fitted later on site. The manufacturer states that filter replacement is particularly easy and selective with 3-filter systems.
Why metric widths?
Most safety cabinets, including Berner's own claire pro, follow HEPA filter sizes in feet, so their outer dimensions are fractional: a claire pro 130 is 1352 mm wide and 815 mm deep. claire neo is 1200, 1500, 1800 or 2100 mm wide and 800 mm deep. This 30 cm grid fits modern laboratory furniture and digital planning and makes later rearrangement easier.
Can the working height be adjusted?
Yes. On the standard base frame the worktop height is set between 650 and 1000 mm in 8 steps. On the electric base frame it moves infinitely between 725 and 1125 mm, so each user can set it for sitting or standing.
How much energy does it use?
The catalogue gives 165 W in ECO mode and 236 W in GMP mode for the B-3-150, without extra consumers. EC fans, LED lighting and the touch display in dark mode keep it low. The optional Energy Save Mode dims light and display further, and the optional auto on/off function shuts the cabinet down in a controlled way when nobody is in front of it.
Who is the Berner claire neo distributor in Türkiye (Turkey)?
Melekırmak is the Türkiye distributor of Berner International. Write to us for a quote, the configuration (width, 2 or 3 filters, base frame, worktops, options) and product documents.
Does the cabinet need regular testing?
Yes. The manufacturer writes that safety cabinets need regular inspection and maintenance by certified service technicians to DIN EN 12469 and DIN 12980, for lasting staff and product protection and for legal compliance. The tests cover the HEPA filters, the inflow and downflow, the alarm limits and the electrical safety.
What is the HS code for the claire neo safety cabinet?
This page does not state an HS code. The customs tariff line depends on the exact model and on the tariff of the destination country. Ask for the HS code of your model together with an export quote: give the model, the quantity and the destination country, and write to us with the contact details at the foot of this page.
Updated: 04.11.2026