Oncology · Drug preparation

claire® neo Safety Cabinet

A safety cabinet for work with cytostatics and hazardous biological material. The width is chosen in 30 cm steps, and the third HEPA filter stage can be added later.

Manufacturer: Berner International

This page is intended for healthcare professionals.

30 cmwidth steps, from 1200 to 2100 mm
H14main, recirculation and exhaust filter, E ≥ 99.995%
ISO 5in the workspace, EC GMP grade A
725-1125 mmworktop height on the electric base frame, infinitely variable
Features

Six details

claire neo safety cabinet with a white powder-coated casing and a monitor in the back wall
  1. 1

    Shield design

    The Shield Design brings form and function together. The manufacturer states that claire neo received the Red Dot Design Award 2024 and two iF Design Awards 2025, for product design and user interface.

  2. 2

    LED status light

    Besides the LED light of the workspace, light bands at the sides and the illuminated window edge in the user's view show the operating state and alarms.

  3. 3

    Touch control

    Swipe gestures work with gloves; 15 function keys are assigned by drag and drop; users log in with a code or an RFID chip.

  4. 4

    Movement-Measurement-System

    It detects people moving near the work opening and the air disturbance they cause, and gives a clear warning.

  5. 5

    Monitor in the back wall

    A 22-inch monitor can be fitted into the back wall on site, later as well.

  6. 6

    Height and legroom

    The first main filter stage is compact, so there is room for the legs even with 3 filters. The electric base frame moves the worktop between 725 and 1125 mm.

Filters

From 2 filters to 3, on site

The airflow of claire neo leaves room for a third HEPA filter stage under the worktop. It can be ordered with the cabinet or fitted later.

Side section of claire neo with the filter positions 3 2 1
  1. 3
    Exhaust filteron top, filters the air leaving the cabinet
  2. 2
    Recirculation filterabove the workspace, gives the clean downflow
  3. 1
    Main filterunder the worktop, only in the 3-filter system
  • All filters at least H14 to DIN EN 1822-1.
  • The third stage can be fitted on site later; almost all parts of the 2-filter cabinet stay in use.
  • The manufacturer calls the third stage useful or even necessary for cytostatics and hazardous biomaterials.
Sizes

Four widths, one 30 cm grid

Most safety cabinets follow HEPA filter sizes in feet, so their outer dimensions are fractional. claire neo is built in 30 cm steps at a standard depth of 800 mm: it lines up with laboratory furniture and digital room planning.

The four outer widths of claire neo to scale1200150018002100
outer, mmworkspace: 1100 / 1400 / 1700 / 2000 mmdepth: 800 mm
Controls

Operated by touch, linked by OPC UA

Gloved finger on the claire neo touch display

On the display

  • Energy-saving dark mode
  • Swipe gestures, also with gloves
  • 15 function keys, assigned by drag and drop
  • Login by code or RFID chip, user profiles
  • Interactive error messages
  • Touch-free start with the foot sensor
  • Cleaning monitoring you can set up yourself

Digital link

  • Optional OPC UA interface
  • Link to laboratory monitoring and cleanroom control systems
  • Record of all logins, alarms and errors
  • Prepared for remote diagnosis and maintenance

Auto on/off

With the optional auto on/off function the cabinet notices that the user has left and shuts down in a controlled way. When the user comes back, ventilation and light switch on and the front window opens by itself.

A worktop segment lifted out of the claire neo workspace
Worktops

Worktops that change with the work

  • New worktop without ventilation slots: easier to clean, 12% more work surface
  • Segment sets 244 mm and 300 mm wide; also 600, 900 mm and other sizes
  • Reinforced worktops for weighing
  • White safety glass worktops for a brighter workspace
  • All worktops fit every claire neo model and can be combined

Worktops with a function

  • Magnetic stirrer
  • Temperature control
  • LED backlight
  • Keyboard

Built in flush and liquid-tight, usable as a normal surface when off, powered from below by plug and play, switched on from the touch display; the user fits and removes them.

Long life

Long life and conversion

The manufacturer's figures. Moving from 2 to 3 filters needs no new cabinet, and the metric grid makes rearranging the room easier.

> 15 yearstypical design life of the components, wear parts excepted
> 95%of the added value created in Germany
ECOtested basic setting instead of GMP mode, with EC fans and dimmable LED
Metalmain components, fully recyclable
claire neo and the taller claire neo XL side by side
neo XL

claire neo XL: twice the depth

The large model of the same family, for laboratory robots, liquid handling systems, bioreactors and other bulky equipment. Several units join side by side into a containment line of several metres.

claire neoclaire neo XL
Outer width1200 / 1500 / 1800 / 2100 mm1500 / 1800 mm
Depth800 mm1300 mm
Height, standard base frame1967-2317 mm2630-3080 mm
Workspace width1100 / 1400 / 1700 / 2000 mm1400 / 1700 mm
Workspace depth475 mm950 mm
Workspace height634 mm990-1100 mm
Worktop height, electric base frame725-1125 mm760-1160 mm
Filters2 or 3, at least H142 or 3, at least H14
TypeBiological or cytostatic safety cabinetClass II biological or cytostatic safety cabinet

Technical data

Type of device
Biological safety cabinet or cytostatic safety cabinet
Type of construction
DIN EN 12469:2026 or DIN 12980:2017-05
Marking and certificate
CE; TÜV GS; quality management to DIN EN ISO 9001
Outer width
1200, 1500, 1800 and 2100 mm
Depth
800 mm
Height
Standard base frame 1967 to 2317 mm; electric base frame 2042 to 2442 mm
Clearance (H x D)
Standard base frame 1947 x 800 mm; electric base frame 2022 x 800 mm
Worktop height
Standard base frame 650 to 1000 mm in 8 steps; electric base frame 725 to 1125 mm, infinitely variable
Filters
Main, recirculation and exhaust filter at least H14 (E ≥ 99.995%) to DIN EN 1822-1, at the most penetrating particle size
Cleanroom class in the workspace
EC GMP guidelines: A; DIN EN ISO 14644-1: ISO class 5
Nominal illuminance
min. 1 to 1200 lx
Vibration on the worktop (RMS)
≤ 5 µm
Sound pressure level (ISO 11201)
< 65 dB(A)
Workspace
1.5 mm stainless steel 1.4301 (V2A), 400 grit fine finish, Ra < 0.8 µm
Casing
Powder-coated 1.5 mm zinc-coated steel sheet 1.0330; white RAL 9003 matt as standard, black RAL 9005 matt as an option
Front and side panels
Laminated safety glass with a UV-absorbing interlayer
Mains
230 V AC, 50/60 Hz
Power consumption ECO / GMP
165 / 236 W (B-3-150, without extra consumers)

Frequently asked questions

What is a cytotoxic safety cabinet, and is claire neo one?

A cytotoxic (cytostatic) safety cabinet protects the person compounding, the drug and the room while hazardous drugs are prepared. In Germany its type is set by DIN 12980. The catalogue lists claire neo either as a biological safety cabinet to DIN EN 12469:2026 or as a cytostatic safety cabinet to DIN 12980:2017-05. For work with cytostatics the manufacturer calls the third HEPA filter stage useful or even necessary.

Is claire neo a class II biological safety cabinet?

For claire neo the catalogue names the type of construction: DIN EN 12469:2026, the European standard for microbiological safety cabinets, or DIN 12980:2017-05. The larger claire neo XL of the same family is described there as a class II biological safety cabinet. The manufacturer states that both cabinets are already tested to the new DIN EN 12469:2026 and its stricter personnel, product and cross-contamination protection.

Which version suits a chemotherapy compounding unit?

For compounding cytostatics the cabinet is ordered as a cytostatic safety cabinet with the 3-filter system. The width follows the room and the number of people working: 1200, 1500, 1800 or 2100 mm. A unit that starts with a 2-filter cabinet can have the third filter stage fitted on site later. SealSafe® Pro can stand next to the cabinet and seal the waste.

What is the difference between the 2-filter and the 3-filter system?

Both have a recirculation filter above the workspace and an exhaust filter on top. The 3-filter system adds a main filter stage under the worktop: the air drawn out of the workspace passes this filter first. All three are at least H14. On claire neo this stage is compact enough to keep the legroom and can be fitted later on site. The manufacturer states that filter replacement is particularly easy and selective with 3-filter systems.

Why metric widths?

Most safety cabinets, including Berner's own claire pro, follow HEPA filter sizes in feet, so their outer dimensions are fractional: a claire pro 130 is 1352 mm wide and 815 mm deep. claire neo is 1200, 1500, 1800 or 2100 mm wide and 800 mm deep. This 30 cm grid fits modern laboratory furniture and digital planning and makes later rearrangement easier.

Can the working height be adjusted?

Yes. On the standard base frame the worktop height is set between 650 and 1000 mm in 8 steps. On the electric base frame it moves infinitely between 725 and 1125 mm, so each user can set it for sitting or standing.

How much energy does it use?

The catalogue gives 165 W in ECO mode and 236 W in GMP mode for the B-3-150, without extra consumers. EC fans, LED lighting and the touch display in dark mode keep it low. The optional Energy Save Mode dims light and display further, and the optional auto on/off function shuts the cabinet down in a controlled way when nobody is in front of it.

Who supplies Berner claire neo in Türkiye?

Melekırmak is the Türkiye distributor of Berner International. Write to us for a quote, the configuration (width, 2 or 3 filters, base frame, worktops, options) and product documents.

Does the cabinet need regular testing?

Yes. The manufacturer writes that safety cabinets need regular inspection and maintenance by certified service technicians to DIN EN 12469 and DIN 12980, for lasting staff and product protection and for legal compliance. The tests cover the HEPA filters, the inflow and downflow, the alarm limits and the electrical safety.

Updated: 04.11.2026

A claire neo for your unit?

Write to us for a quote, the configuration or product documents.