Endobronchial Blocker

An endobronchial blocker (bronchial blocker) is a thin catheter whose cuff is inflated in a main bronchus to close off that lung for one-lung ventilation. It is passed through an existing endotracheal tube or laryngeal mask, which keeps the airway, and works on the left or right side. A double lumen tube is a separate product.

Manufacturer: Tuoren Medical3 models

This page is intended for healthcare professionals.

Models

SizeModel
5.0EBN050
7.0EBN070
9.0EBN090

Bronchial blocker used through an endotracheal tube or laryngeal mask for one-lung ventilation, left or right; blue silicone cuff, sizes 5.0, 7.0, 9.0.

What is it used for?

  • Thoracic surgery that needs one-lung ventilation.
  • A patient in whom a double lumen tube is hard to place, or who is already intubated with a single lumen tube.
  • Ventilation that continues after surgery without changing the tube.
  • One-lung ventilation in a patient whose airway is kept with a laryngeal mask.

What makes it different?

  • With a tube or a mask The blocker is used with endotracheal tubes and laryngeal masks, on the left or right side.
  • No tube change After one-lung ventilation the single lumen tube does not need replacing; the manufacturer states this is to avoid the damage a second intubation would cause.
  • Thin, flexible body The manufacturer states that the body is thin and elastic, and that the distal curve makes positioning easier.
  • Articulated connector The manufacturer states that oxygen supply, secretion suction and examination can be done through the joint at the same time.
  • Blue silicone cuff The cuff is soft medical silicone and blue; the manufacturer states that the blue colour makes the cuff easier to identify and position.

One-lung ventilation: double lumen tube, camera tube and bronchial blocker

FeatureDouble and Single Lumen Endobronchial Tube Coming SoonDouble Lumen Endobronchial Tube with Camera Coming SoonEndobronchial Blocker Coming Soon
How it separates the lungsDouble lumen tubeTwo lumens reach the lungs separatelyCamera tubeTwo lumens, with a camera built into the tubeBlockerIts cuff is inflated in a main bronchus to close off that side
Checking the positionDouble lumen tubeUsually confirmed with a fiberoptic bronchoscopeCamera tubeWatched on the monitor throughout intubation, with an alarm on displacementBlockerA bronchoscope is usually used for positioning
AirwayDouble lumen tubeSets up a unilateral or bilateral artificial airwayCamera tubeA double lumen endobronchial tubeBlockerAn existing endotracheal tube or laryngeal mask
SizesDouble lumen tube26 to 41 Fr, nine sizes, left and rightCamera tube26 to 41 Fr, left and right, Type I and Type IIBlocker5.0, 7.0 and 9.0

Frequently asked questions

What is an endobronchial blocker (bronchial blocker), and how does it work in anesthesia?

An endobronchial blocker is a thin catheter whose cuff is inflated in a main bronchus to close off that side, so that one-lung ventilation is achieved. It is passed through an existing endotracheal tube or laryngeal mask, which keeps the airway. Physicians call it a bronchial blocker; in purchasing the name endobronchial blocking tube is also used.

Bronchial blocker or double lumen tube: when is each used?

The physician chooses for the surgery and the patient's airway. A blocker is considered when the patient is already intubated with a single lumen tube, when a double lumen tube is hard to place, or when ventilation is to continue after surgery without a tube change. A double lumen tube reaches each lung through its own lumen. The summary of comparative studies is on the double lumen tube page.

Which sizes are available, and which tube do they fit?

The blocker comes in three sizes: 5.0, 7.0 and 9.0. It is used with endotracheal tubes and laryngeal masks, on the left or right side. This page does not list which tube inner diameter or patient group each size matches. The physician chooses the size.

How is the blocker placed, and is a bronchoscope needed?

A bronchoscope is usually used for positioning. The blocker is advanced through the tube or mask in place, and its cuff is inflated in the target bronchus. The manufacturer states that oxygen, suction and examination can run through the articulated connector at the same time, and that the blue cuff is easier to identify and position. The cuff inflation volume is not given on this page.

Does the tube need changing after one-lung ventilation?

If a single lumen tube is in place, it does not need replacing after the blocker is used. When the blocker cuff is deflated and the blocker withdrawn, both lungs are ventilated again through the same tube. The manufacturer states that this is to avoid the damage a second intubation would cause. If the patient needs ventilation after surgery, it can continue through the same tube; the physician decides.

What is the blocker made of?

The cuff is soft medical silicone and blue. The body is thin and flexible, with a distal curve that the manufacturer designed to make positioning easier. The manufacturer states that the articulated connector allows oxygen, suction and examination at the same time. The body material, length and packaging are not given on this page.

What are Arndt, Cohen and EZ-Blocker?

Arndt and Cohen are brand names that Cook Medical uses for endobronchial blockers, and EZ-Blocker is a brand name of Teleflex. The names belong to their owners; the blocker on this page is not one of these brands. This page does not compare products.

Can I order the endobronchial blocker in Türkiye, and what is the price?

We can share the product documents and the three sizes with their model codes, and answer technical questions about the blocker. Not yet: the endobronchial blocker is not available for order in Türkiye, so this page carries no list price. Write to us with the button on this page for information.

Technical data

Manufacturer
Tuoren Medical
Used with
Endotracheal tube or laryngeal mask; left or right bronchus
Cuff
Soft medical silicone, blue
Body
Thin and flexible, with a distal curve
Connector
Articulated; oxygen, suction and examination at the same time