Coming Soon

Double Lumen Endobronchial Tube with Camera

A double lumen endobronchial tube with camera (video double lumen tube) is a double lumen tube with a camera built into the tube. The image goes to the TR-V-01 video device, the tube position is watched throughout intubation, and an automatic alarm is given on displacement. A bronchoscope is a separate device.

Manufacturer: Tuoren Medical36 models

This page is intended for healthcare professionals.

Measurements at a glance

Size
26 to 41 Fr
by model

Models

Size (Fr)SideModel
Type I, left
26LeftCDENL1026
28LeftCDENL1028
31LeftCDENL1031
32LeftCDENL1032
33LeftCDENL1033
35LeftCDENL1035
37LeftCDENL1037
39LeftCDENL1039
41LeftCDENL1041
Type I, right
26RightCDENR1026
28RightCDENR1028
31RightCDENR1031
32RightCDENR1032
33RightCDENR1033
35RightCDENR1035
37RightCDENR1037
39RightCDENR1039
41RightCDENR1041
Type II, left
26LeftCDENL2026
28LeftCDENL2028
31LeftCDENL2031
32LeftCDENL2032
33LeftCDENL2033
35LeftCDENL2035
37LeftCDENL2037
39LeftCDENL2039
41LeftCDENL2041
Type II, right
26RightCDENR2026
28RightCDENR2028
31RightCDENR2031
32RightCDENR2032
33RightCDENR2033
35RightCDENR2035
37RightCDENR2037
39RightCDENR2039
41RightCDENR2041
Video device
TR-V-01 monitor; photo and video recording

Double lumen tube with camera that shows its position on a monitor and alarms on displacement; left and right, 26 to 41 Fr, Type I and II.

What is it used for?

  • Thoracic surgery that needs one-lung ventilation, such as lobectomy or VATS.
  • Lung isolation, where one lung has to be ventilated apart from the other.
  • Watching the tube position on the monitor during surgery, for example after the patient is turned to the lateral position.

What makes it different?

  • Continuous position view The camera is built into the tube, the position is watched on the monitor throughout intubation, and an automatic alarm is given on displacement.
  • Horseshoe-shaped tip The manufacturer states that the horseshoe shape of the endobronchial end is designed to help guide the tip into the bronchus.
  • One-handed connector The manufacturer states that the multi-function connector with its control valve allows one-handed use and a quick change to one-lung ventilation.
  • Coated lens The manufacturer states that the lens has a special coating to keep secretions from sticking to it.
  • Recording Photos and video can be recorded for case analysis and teaching.

One-lung ventilation: double lumen tube, camera tube and bronchial blocker

FeatureDouble and Single Lumen Endobronchial Tube Coming SoonDouble Lumen Endobronchial Tube with Camera Coming SoonEndobronchial Blocker Coming Soon
How it separates the lungsDouble lumen tubeTwo lumens reach the lungs separatelyCamera tubeTwo lumens, with a camera built into the tubeBlockerIts cuff is inflated in a main bronchus to close off that side
Checking the positionDouble lumen tubeUsually confirmed with a fiberoptic bronchoscopeCamera tubeWatched on the monitor throughout intubation, with an alarm on displacementBlockerA bronchoscope is usually used for positioning
AirwayDouble lumen tubeSets up a unilateral or bilateral artificial airwayCamera tubeA double lumen endobronchial tubeBlockerAn existing endotracheal tube or laryngeal mask
SizesDouble lumen tube26 to 41 Fr, nine sizes, left and rightCamera tube26 to 41 Fr, left and right, Type I and Type IIBlocker5.0, 7.0 and 9.0

Frequently asked questions

What is a double lumen tube with camera (video double lumen tube)?

It is a double lumen endobronchial tube with a camera built into the tube, used for one-lung ventilation. The camera image goes to the TR-V-01 video device, so the tube position can be watched throughout intubation, and an automatic alarm is given on displacement. Photos and video can be recorded for case analysis and teaching.

How does it differ from a standard double lumen tube and from a bronchoscope?

The difference is in seeing the position. With a standard double lumen tube (DLT), the final position is usually confirmed with a fiberoptic bronchoscope. In the camera tube the camera is built into the tube, and the position shows on the monitor throughout the case. A bronchoscope is a separate device. The standard tube, in purchasing also written as endobronchial tube, right/left, has its own page on this site.

Which sizes and sides are available?

The tube comes left and right in nine sizes from 26 to 41 Fr: Fr26, 28, 31, 32, 33, 35, 37, 39 and 41. Type I and Type II come in the same sizes and sides. This page does not list the difference between the two types; write to us for information. The physician picks the side and size for the surgery and the patient's airway.

How does the displacement alarm work?

When the tube moves out of position, the system gives an automatic alarm. The manufacturer states that the alarm is there to make observation and repositioning during surgery easier. Repositioning is the anesthesia team's decision. The alarm criteria and settings are not given on this page.

Which video device does it work with, and can it record?

The tube works with the TR-V-01 video device, a monitor. It records photos and video, which can be used for case analysis and teaching. The same video device is listed for the video laryngeal mask airway on this site. Screen size, battery and storage are not given on this page.

Is there a study on bronchoscope use with double lumen tubes with a camera?

A published study exists for this class of device; it was not done with this tube. In a single-centre randomised study of 80 patients with another manufacturer's double lumen tube with camera, bronchoscope use to verify the final position was 13.2% (5/38) with the camera tube and 100% (42/42) with a standard tube; bronchoscope use to correct displacement was 7.7% (1/13) and 100% (14/14). The rate of displacement did not differ significantly between the groups (Heir et al., J Cardiothorac Vasc Anesth 2017). Keeping a bronchoscope ready is the physician's decision.

Can I order the double lumen tube with camera in Türkiye, and what is the price?

We can share the product documents, the list of sizes, sides and types with model codes, and answer technical questions about the tube. Not yet: the double lumen tube with camera is not available for order in Türkiye, so this page carries no list price. Write to us with the button on this page for information.

Technical data

Manufacturer
Tuoren Medical
Types
Type I and Type II, both left and right in the same sizes
Camera
Built into the tube; lens with a coating against secretions
Endobronchial tip
Horseshoe-shaped
Cuff
High-volume, low-pressure
Connector
Multi-function, with control valve, for one-handed use

Updated: 10.11.2026

This product is not yet available for order in Türkiye. We can share the product documentation and the manufacturer's data.